5 Port Circulators
Available in most frequency ranges with Port 2 optimized for reactance amplifier application. Also 6 or 7 port variations and "Pi" configurations. Two ports are terminated with 1 Watt loads.
|
Typical Specifications |
Isolation: |
(2-1) |
40 dB min |
|
(3-2) |
40 dB min
(2 integral terminations) |
| Insertion Loss: |
(1-2) |
0.60 dB max |
|
(2-3) |
0.60 dB max |
| VSWR: |
(all ports) |
1.25 : 1 max |
|
|